Reply by while(1); October 18, 20102010-10-18
> We are using ADIS 16405 IMU from Analog Devices in our application,we are > using SPI interface for collecting the data from IMU.We are able to get > the correct data but once in a while data shows 0x0000. Earlier we > thought that it might be the problem with power glitches and used > regulated 5v dc source but still the same problem is coming.we are > operating the device with clock rate of 117.9647 k Hz,IMU in a slave mode > and Master is ADSP 21262 DSP processor based kit .Please help us with > this. > > regards....... > > SUresh .M >
Did you check if your SPI interface is configured propely? Sometimes sampling on wrong clock edge works, but unreliably - like in your case... - while(1);
Reply by Mamidipalli October 18, 20102010-10-18
hi .....


We are using ADIS 16405 IMU from Analog Devices in our application,we are
using SPI interface for collecting   the data from IMU.We are able to get
the correct  data but once in a while data shows 0x0000. Earlier  we
thought that it  might be the problem with power glitches and used
regulated 5v dc source but still the same problem is coming.we are
operating the device with clock rate of 117.9647 k Hz,IMU in a slave mode
and Master is ADSP 21262 DSP processor based kit .Please help us with
this.

regards.......

SUresh .M

	   
					
---------------------------------------		
Posted through http://www.EmbeddedRelated.com