"Pascal Garcia" <pgarcia@irisa.fr> wrote in message
news:e10nld$5f4$1@amma.irisa.fr...
> Hi,
>
> sorry if this is off-topic, but reading the datasheet of the 8253, I don't
> understand the sentence concerning the mode 2 and 3 :
> "In modes 2 and 3, if a CLK source other than the system clock is used,
> GATE should be pulsed immediately following /WR of a new count value"
>
> can somebody help me ?
>
> pascal
>
What the datasheet is trying hard to not say
is that the counter has a flaw in the design.
When operating in auto reload (rate generator
or square wave) modes with an external clock
source the internal state of the GATE input
may be ambiguous after an update of the terminal
count value of the counter.
Why the internal state of the GATE input maybe
be wrong under these conditions is a somewhat
involved explanation.
The solution suggested by the datasheet will
force the internal state of the GATE input
to a known state with the side affect of
causing the counter to restart and load
the new terminal count value on the next
external clock pulse.
Getting the 8253 to work correctly with an
external clock can be quite a challenge when
using modes 2 and 3.
Reply by Pascal Garcia●April 5, 20062006-04-05
Hi,
sorry if this is off-topic, but reading the datasheet of the 8253, I
don't understand the sentence concerning the mode 2 and 3 :
"In modes 2 and 3, if a CLK source other than the system clock is used,
GATE should be pulsed immediately following /WR of a new count value"
can somebody help me ?
pascal