Hello Alex, this is done using the burner utility (either standalone or CodeWarrior). If you have a .bbl (batch burner language) command file in your project, this is automatically processed after linking in CodeWarrior. I will send you TN93 off-list. The Technical Note TN93 has this as subject ("Generating Motorola S File for a Banked Application"). The technical notes are installed with the CodeWarrior software (however not in the 'compact' installation setup): go to the 'setup or uninstall' shortcut created by the installer to have them all installed. Erich > -----Original Message----- > From: Alexandre Plombin [mailto:] > Sent: Thursday, August 29, 2002 5:40 PM > To: ; > Subject: [68HC12] Hiware compiler, Star12, and linear addressing > Hi, > > Has anyone had issues working with linear addressing on the Star12 DP256, generating a true linear s-record (0x0C.0000 to > 0x0F.FFFF ... thanks Gordon!) with the Hiware (hum, Metrowerks) compiler? > > It seems that Hiware is using the linear addresses during symbol resulution at linktime, therefore the code does not > work, since it expects the addresses to be in the page # + page window offset format. > > Can I do this properly using the Hiware linker, or is my best bet just using banked addresses at linktime and then using > a physical -> logical converter on the linker output? > > Thanks, > > Alex. > -------------------- > > ">http://docs.yahoo.com/info/terms/ |