Amphenol All Sensors Corporation
Pressure Sensor 15PSI (103.42kPa) Differential Male - 0.19" (4.83mm) Tube, Dual 0 mV ~ 90 mV (12V) 6-SIP Module
Active84 in stock

Overview

The 15 PSI-D-HGRADE-MV is a high-grade differential pressure sensor designed for precise measurements in the 0 to 15 PSI range. It utilizes a silicon micro-machined Wheatstone bridge technology coupled with internal temperature compensation to provide a stable millivolt output. This through-hole sensor is housed in a 6-SIP module with dual 0.19-inch barbless ports, making it suitable for board-level integration in pneumatic systems.

Why Choose This Part

This sensor offers a high accuracy of +/-0.5%, ensuring reliable data for sensitive control loops. The internal temperature compensation maintains performance across a 0 to 70 degrees Celsius range, while the millivolt output allows for flexible signal conditioning design using standard instrumentation amplifiers.

Applications

Medical Instrumentation
Used in patient monitoring and respiratory equipment where precise differential air pressure measurement is critical.
HVAC System Monitoring
Ideal for measuring filter pressure drops and duct airflow in environmental control systems.
Industrial Pneumatics
Monitors pressure differentials in factory automation and process control lines to ensure system integrity.
Environmental Controls
Integrated into cleanroom monitoring systems to maintain specific pressure gradients between zones.

Key Specifications

Output 0 mV ~ 90 mV (12V)
Accuracy +/-0.5%
Features Temperature Compensated
Port Size Male - 0.19" (4.83mm) Tube, Dual
Port Style Barbless
Output Type Wheatstone Bridge
Applications Board Mount
Mounting Type Through Hole
Pressure Type Differential
Package / Case 6-SIP Module
Maximum Pressure 60PSI (413.69kPa)
Voltage - Supply 16V
Termination Style PC Pin
Operating Pressure 15PSI (103.42kPa)
Operating Temperature -25degC ~ 85degC

Getting Started

To interface this sensor, connect the Wheatstone bridge output to a high-impedance instrumentation amplifier to scale the 0-90mV signal for an ADC. Ensure the excitation voltage does not exceed the 16V maximum rating, with 12V being the typical reference for the specified output range. The dual barbless ports accept standard 0.19-inch tubing for easy plumbing in differential configurations.