85-100A-0R 100 PSI Absolute Pressure Sensor

85-100A-0R 100 PSI Absolute Pressure Sensor

MPN: 85-100A-0R
TE Connectivity Measurement Specialties
Pressure Sensor 100PSI (689.48kPa) Absolute 0 mV ~ 100 mV Cylinder
Active155 in stock

Overview

The 85-100A-0R is a small, media-compatible pressure sensor from TE Connectivity featuring a 316L stainless steel housing and an oil-filled sensing element. It provides an unamplified 0-100 mV Wheatstone bridge output from an absolute pressure range of 0 to 100 PSI with high accuracy of +/-0.1%. Designed for weldable mounting, this sensor is temperature compensated and can operate in harsh environments from -40C up to 125C.

Why Choose This Part

This sensor offers excellent long-term stability and 0.1% accuracy in a compact, weldable form factor that simplifies mechanical integration. The use of 316L stainless steel ensures compatibility with most liquids and gases while the 12-bit resolution capability allows for precise pressure measurement.

Applications

Medical Instrumentation
High-accuracy pressure monitoring in diagnostic equipment and fluid management systems requiring stainless steel compatibility.
Industrial Process Control
Monitoring hydraulic and pneumatic systems where the sensor must withstand corrosive media or high temperatures.
Hydraulic Pressure Sensing
Ideal for heavy machinery and manufacturing equipment due to its 300 PSI maximum overpressure rating.
Diving Computers
Used in depth and pressure monitoring systems that require a rugged, absolute pressure reference.

Key Specifications

Output 0 mV ~ 100 mV
Accuracy +/-0.1%
Features Temperature Compensated
Port Style No Port
Output Type Wheatstone Bridge
Applications Board Mount
Pressure Type Absolute
Package / Case Cylinder
Maximum Pressure 300PSI (2068.43kPa)
Termination Style Cable with Connector
Operating Pressure 100PSI (689.48kPa)
Operating Temperature -40degC ~ 125degC

Getting Started

To use this sensor, provide a stable excitation voltage between 0.5V and 2.0V to the Wheatstone bridge. The differential millivolt output typically requires a high-precision instrumentation amplifier or a dedicated 24-bit Sigma-Delta ADC like the ADS1220 to convert the raw signal into a digital value.