1 kOhms RTD Platinum (Pt) ±0.1% Cylindrical Probe, Ceramic
Active2,740 in stock

Overview

The HEL-705-U-1-12-00 is a high-accuracy 1000 Ohm platinum Resistance Temperature Detector (RTD) housed in a durable alumina ceramic tube. It is designed to provide linear temperature sensing from -70 degrees Celsius to 260 degrees Celsius, featuring 28 AWG PTFE-insulated lead wires for reliable connectivity. This thin-film sensor offers stable performance and is interchangeable without the need for individual recalibration due to its strict +/-0.1% resistance tolerance.

Why Choose This Part

This RTD features a high 1 kOhm nominal resistance, which reduces the impact of lead wire resistance errors compared to standard 100 Ohm sensors. Its ceramic probe construction provides excellent environmental protection and electrical insulation in harsh mounting conditions. The +/-0.3 degree Celsius accuracy at 0 degrees Celsius ensures high-fidelity data for sensitive feedback loops.

Applications

HVAC System Monitoring
Used in air duct and climate control systems where accurate air temperature measurement is required for efficiency.
Industrial Process Control
Monitoring temperature in chemical or manufacturing processes that operate within a -70C to 260C range.
Laboratory Equipment
Integration into ovens, incubators, or environmental chambers that require precision RTD feedback.
Medical Instrumentation
Suitable for diagnostic or sterilization equipment requiring stable and repeatable thermal sensing.

Key Specifications

Current 1 mA
Accuracy +/-0.3degC
Termination Wire Leads
RTD Material Platinum (Pt)
Mounting Type Free Hanging
Package / Case Cylindrical Probe, Ceramic
Resistance @ 0degC 1 kOhms
Resistance Tolerance +/-0.1%
Operating Temperature -70degC ~ 260degC

Getting Started

To use this sensor, connect the wire leads to a high-resolution ADC through a precision current source or a bridge circuit. Given the 1 mA maximum current spec, ensure your excitation current is low to prevent self-heating errors. Implement the Callendar-Van Dusen equation in your firmware to linearize the resistance-to-temperature conversion across the operating range.