EmbeddedRelated.com
MIPAF1XX150PAAAX

MIPAF1XX150PAAAX

Honeywell Sensing and Productivity Solutions
Pressure Sensor 150PSI (1034.21kPa) Absolute Female - 7/16" (11.11mm) UNF Schrader 0.5 V ~ 4.5 V Cylinder, Threaded
Active71 in stock

Overview

The MIPAF1XX150PAAAX is a heavy-duty, media-isolated pressure transducer designed for use with a wide range of liquids and gases. It features a rugged stainless steel construction and provides a ratiometric analog voltage output from 0.5 V to 4.5 V over a 150 PSI absolute pressure range. This sensor is temperature-compensated and built to operate in harsh environments with high accuracy and electromagnetic compatibility.

Why Choose This Part

This transducer offers industry-leading accuracy of +/-0.15% and includes built-in protection against load dump, reverse voltage, and electrical surges. Its stainless steel housing and Metri-Pack 150 connector provide a hermetic seal and high vibration resistance for long-term reliability in demanding field conditions.

Applications

Industrial HVAC and Refrigeration
Monitoring pressure in compressors and coolant lines where media compatibility and durability are essential.
Medical Ventilation Systems
Providing precise absolute pressure measurements for respiratory support equipment in clinical settings.
Process Control
Measuring pressure in food and beverage processing or oil and gas applications requiring NSF/ANSI/CAN 61 certification.
Hydraulic and Pneumatic Systems
Reliable feedback for heavy machinery and compressed air systems operating up to 125 degrees Celsius.

Key Specifications

Output 0.5 V ~ 4.5 V
Accuracy +/-0.15%
Features Temperature Compensated
Port Size Female - 7/16" (11.11mm) UNF Schrader
Port Style Threaded
Output Type Analog Voltage
Applications Medical Ventilation
Pressure Type Absolute
Package / Case Cylinder, Threaded
Maximum Pressure 348.09PSI (2400kPa)
Voltage - Supply 4.75V ~ 5.25V
Termination Style Connector
Operating Pressure 150PSI (1034.21kPa)
Operating Temperature -40degC ~ 125degC

Getting Started

To integrate this sensor, provide a stable 5V DC supply to the Metri-Pack 150 connector and interface the analog output to an ADC-equipped microcontroller. Ensure the 7/16-20 UNF female thread is properly seated with compatible fittings to maintain the absolute pressure reference. Use a 10kOhm or higher input impedance on your measurement circuit to prevent loading the 0.5V to 4.5V signal.