EmbeddedRelated.com
Jacob Beningo
Live online course · Jacob Beningo
AI for Embedded Developers
$100 off for EmbeddedRelated readers until Dec 6 · 5 live sessions, Dec 7-11
Discount ends in
27days 04hrs 39min 00sec
Learn More →
SDP806-500PA

SENSDP806-500PA

Sensirion AG
Pressure Sensor 0.07PSI (0.5kPa) Differential Male - 0.2" (5.2mm) Tube, Dual 0.5 V ~ 4.5 V Module
Active91 in stock

Overview

The SDP806-500PA is a high-performance differential pressure sensor designed for high-volume applications. It utilizes Sensirion's CMOSens technology to provide an analog voltage output that is fully calibrated and temperature compensated over a range of -20C to 85C. This sensor is specifically engineered for measuring differential pressure in air and non-aggressive gases with high precision and no offset drift.

Why Choose This Part

This sensor offers excellent repeatability and a large dynamic range with no zero-point drift, eliminating the need for periodic re-calibration. Its analog output (0.5V to 4.5V) is ratiometric to the supply voltage, making it easy to integrate with standard analog-to-digital converters in embedded systems.

Applications

HVAC Airflow Control
Ideal for VAV (Variable Air Volume) controllers and filter monitoring in residential or commercial ventilation systems.
Medical Respiratory Devices
Used in ventilators and anesthesia machines to monitor breathing cycles and gas delivery with high repeatability.
Industrial Process Control
Monitoring pressure drops across filters or heat exchangers in pneumatic systems.
Burner Control
Measuring the air-to-fuel ratio in condensing boilers to optimize combustion efficiency.

Key Specifications

Output 0.5 V ~ 4.5 V
Accuracy +/-3%
Features Temperature Compensated
Port Size Male - 0.2" (5.2mm) Tube, Dual
Port Style Barbless
Output Type Analog Voltage
Applications Board Mount
Pressure Type Differential
Package / Case Module
Maximum Pressure 14.5PSI (100kPa)
Voltage - Supply 3V ~ 5.5V
Operating Pressure 0.07PSI (0.5kPa)
Operating Temperature -20degC ~ 85degC

Getting Started

Integration requires a stable 2.7V to 5.5V supply and a microcontroller with an ADC to read the 0.5V-4.5V output signal. For prototyping, Sensirion offers SEK-SensorBridge which can connect to a PC, though direct PCB mounting using the 0.2 inch tube ports is standard for production.

Also Consider

NPA Series Amphenol Advanced Sensors - An alternative digital differential pressure sensor if a different form factor or digital output is required.
MPXV7002DP NXP USA Inc. - A widely used analog differential pressure sensor suited for lower-cost air flow applications.