Re: i can't use ethernet ram for general purpose

Started by dush...@yahoo.co.in August 3, 2007
if u r using ethernet connection then u could not use ethernet ram for general purpose .........
if u r not then u can use it for general purpose

hi all.
> i use lpc2368.and i want to use ethernet ram for general purpose too.In sct file i used
>
> RAM2 0x7FE00000 0x00003FFF
> {
> * (+RW +ZI)
> }
>
> So all of data will be in ethernet ram.And i tried a basic application(write to uart). But nothing happend.
> Is there anyone who used ethernet ram for general purpose? I wait help.
> So thanks..
> Mehmet Kurnaz
>
>---------------------------------
>The fish are biting.
> Get more visitors on your site using Yahoo! Search Marketing.
>
>
>

An Engineer's Guide to the LPC2100 Series

In order to use the Ethernet RAM, you must set the power/clock bit
for the Ethernet block in the PCONP register (bit 30).

--- In l..., dushyant7891@... wrote:
>
> if u r using ethernet connection then u could not use ethernet ram
for general purpose .........
> if u r not then u can use it for general purpose
>
> hi all.
> > i use lpc2368.and i want to use ethernet ram for general
purpose too.In sct file i used
> >
> > RAM2 0x7FE00000 0x00003FFF
> > {
> > * (+RW +ZI)
> > }
> >
> > So all of data will be in ethernet ram.And i tried a basic
application(write to uart). But nothing happend.
> > Is there anyone who used ethernet ram for general purpose? I
wait help.
> > So thanks..
> > Mehmet Kurnaz
> >
> >---------------------------------
> >The fish are biting.
> > Get more visitors on your site using Yahoo! Search Marketing.
> >
> >
>