Quick Q regarding Ethernet

Started by Trevor Barton June 23, 2004
I'm starting to look at building an ethernet switch for a specialist
application that precludes using an off-the-shelf switch, and I'm interested
in the Realtek RTL8309SB because having pulled apart a couple of switches
and looked at the reference designs it looks like I can do what I want 
by just adding some magnetics and LEDs and nothing much else, and that
means that I don't have to learn too much about Ethernet, because this is
a one-off and I have no forseeable need for an in-depth understanding
of things Ethernet in the future.

However, I might want to connect two RTL8309s together so that I can do
smart things with redundancy on a vulnerable link by switching on or 
off the interconnection.  I can do that in a number of ways that minimise 
my learning curve, for example I could use a relay or a FSAL200 somewhere in
the interconnection link (I have a local controller on the LAN) to either
isolate the link or not.  That will do what what I want, and I don't have to
understand a lot of stuff about Ethernet to do it.

However, if it's worth it, I am of course prepared to go into things more
deeply, but I don't want to go off on a tangent that'll turn out to be
a dead end, so I'm asking for some guidance, particularly because I don't
really know what I'm looking for at this stage.

The RTL8309SB has a 9th port, called an MII port.  Can I use that port
to somehow generate another 4-wire ethernet signal?  Is this to do with using
the port in MII PHY mode or SNI PHY mode?

Alternatively, can I connect together two 8309s with this port and some
glue logic (but *not* a controller of some sort) to extend the number of
ports on my switch? 

I'd appreciate it if someone could tell me if I'm on the right track
or not!

Regards

-- 
Trevor Barton
On 2004-06-23, Trevor Barton <tmb@Xisotek.co.uk> wrote:

> The RTL8309SB has a 9th port, called an MII port. Can I use > that port to somehow generate another 4-wire ethernet signal?
No. MII is a management interface that is used for status/control purposes. It does not transfer Ethernet packets. -- Grant Edwards grante Yow! Oh, FISH sticks, at CHEEZ WHIZ, GIN fizz, visi.com SHOW BIZ!!
Trevor Barton wrote:
> The RTL8309SB has a 9th port, called an MII port. > Can I use that port to somehow generate another > 4-wire ethernet signal? Is this to do with using > the port in MII PHY mode or SNI PHY mode?
MII = Media Independent Interface (or is it Interconnect?) I'd chase this option first. Grant's memory may be better than mine, but IIRC, MII interfaces are intended for using an external PHY (e.g., fiber), and you may find its signaling more compatible for your interests. There should be some more details in the datasheet. Some things to look into - at least Realtek's 10Mb chipset uses this as a multi-function interface, so you'll probably have to select it as MII mode. Also, see if activating this port comes at the expense of disabling anything else (like one of the other ports).
> Alternatively, can I connect together two 8309s > with this port and some glue logic (but *not* a > controller of some sort) to extend the number of > ports on my switch?
There's a possibility you could connect them together, creating a trunk between the 2 switches. So, what particular failover scenario are you trying to achieve? Maybe there's a simpler path to your goal.
On 2004-06-23, Grant Edwards <grante@visi.com> wrote:
> On 2004-06-23, Trevor Barton <tmb@Xisotek.co.uk> wrote: > >> The RTL8309SB has a 9th port, called an MII port. Can I use >> that port to somehow generate another 4-wire ethernet signal? > > No. MII is a management interface that is used for > status/control purposes. It does not transfer Ethernet packets.
Oops. I mis-spoke. MII has two sets of signal lines, one for the serial management interface, the other for data-frames (it's a nibble-wide path, IIRC). I was thinking that MII referred to the management half and there was some other TLA for the data half, but MII is both. -- Grant Edwards grante Yow! Thousands of days of at civilians... have produced visi.com a... feeling for the aesthetic modules --
On Thu, 24 Jun 2004 06:00:43 -0700, Richard wrote:
> Trevor Barton wrote: >> The RTL8309SB has a 9th port, called an MII port. >> Can I use that port to somehow generate another >> 4-wire ethernet signal? Is this to do with using >> the port in MII PHY mode or SNI PHY mode? > > MII = Media Independent Interface (or is it Interconnect?) > > I'd chase this option first. Grant's memory may be better than mine, > but IIRC, MII interfaces are intended for using an external PHY (e.g., > fiber), and you may find its signaling more compatible for your > interests. There should be some more details in the datasheet. > > Some things to look into - at least Realtek's 10Mb chipset uses this as > a multi-function interface, so you'll probably have to select it as MII > mode. Also, see if activating this port comes at the expense of > disabling anything else (like one of the other ports). > > >> Alternatively, can I connect together two 8309s >> with this port and some glue logic (but *not* a >> controller of some sort) to extend the number of >> ports on my switch? > > There's a possibility you could connect them together, creating a trunk > between the 2 switches. > > > So, what particular failover scenario are you trying to achieve? Maybe > there's a simpler path to your goal.
Thanks for the info, you and Grant both. I'll have to look into the MII interface more, then, seeing as it's not neccessarily a non-starter! The failover requirement is that we have a scheme that involves two independant LANs being carried from a subsea to shipboard enviroment. They are independant because under normal circumstances we will use one for high data rate monitoring from one transmitter on the seabed to one receiver on the surface, and the other for overall control of a number of subsea bits of equipment. We want no other data on the high speed link in normal operation. However both links are vulnerable to disruption for one reason or another and if that happens we want to be able to route the two LANs together to bypass the break. There are several of these dual hubs between the deck and the last node, and any interconnect can be broken, so we need to be able to crosslink at any hub if required. An alternative is that the local controller in each hub could act as an intelligent router if we fit them with two NICs, and we could tell them to route between LANs if required. There are advanteges and disadvantages in both approaches, though. Cheers, Trev -- Trevor Barton
Trevor Barton wrote:
> The failover requirement is that we have a scheme > that involves two independant LANs being carried > from a subsea to shipboard enviroment.
A clever approach. Sounds reasonably resilient. I gather you're OK with using a microcontroller, just not to forward data between the switch chips? This is actually a pretty slick chip! It'd be worth your time to study the datasheet - it's got some powerful features for a single-chip solution. 1) Check out the Power-down and Isolate features (section 7.1.1) - this is one easy way to handle what you want. Via an external MCU, just turn the failover ports on & off as needed. Query other status registers to decide when. 2) Even slicker - a one-chip solution. If you use the VLAN features of the switch (section 8.3.1) you can keep your 2 data channels separate while using a single switch chip. Simpler, higher-performance, much better failover ability. E.g., under normal circumstances, ports 1 and 2 (downlinks) are in separate VLANs which only talk to ports 3 and 4 (uplinks), respectively. If any link fails, the MCU simply reconfigures ports to map a spare uplink or downlink cable into the failed VLAN (the two channels only need to be co-mingled as a last resort). This could yield 2 uplinks and 2 downlinks, plus 2 failover ports in each direction - you'd need to lose 3 uplink or downlink cables before you'd have to combine the channels into one VLAN. The only exposure is using a single switch chip (and single MCU). Lastly, use the MII port for the MCU's Etherenet so it can report status remotely.
On Thu, 24 Jun 2004 21:12:28 -0700, Richard wrote:
> Trevor Barton wrote: >> The failover requirement is that we have a scheme >> that involves two independant LANs being carried >> from a subsea to shipboard enviroment. > > A clever approach. Sounds reasonably resilient. I gather you're OK > with using a microcontroller, just not to forward data between the > switch chips?
Yes, the microcontroller (actually a PC104 x86) controls video multiplexing and power distribution as well.
> This is actually a pretty slick chip! It'd be worth your time to study > the datasheet - it's got some powerful features for a single-chip > solution. > > 1) Check out the Power-down and Isolate features (section 7.1.1) - this > is one easy way to handle what you want. Via an external MCU, just turn > the failover ports on & off as needed. Query other status registers to > decide when. > > 2) Even slicker - a one-chip solution. If you use the VLAN features of > the switch (section 8.3.1) you can keep your 2 data channels separate > while using a single switch chip. Simpler, higher-performance, much > better failover ability. > > E.g., under normal circumstances, ports 1 and 2 (downlinks) are in > separate VLANs which only talk to ports 3 and 4 (uplinks), > respectively. If any link fails, the MCU simply reconfigures ports to > map a spare uplink or downlink cable into the failed VLAN (the two > channels only need to be co-mingled as a last resort). This could yield > 2 uplinks and 2 downlinks, plus 2 failover ports in each direction - > you'd need to lose 3 uplink or downlink cables before you'd have to > combine the channels into one VLAN. > > The only exposure is using a single switch chip (and single MCU). > Lastly, use the MII port for the MCU's Etherenet so it can report status > remotely.
Thanks, Richard, a few good ideas to look into there. The VLAN idea sounds neat, but I think I'm going to run into problems with the number of ports anyway, because I actually need 9 per side although I think I cna squeeze it into 8. Direct connection to the controller sounds interesting, though. Cheers, Trev -- Trevor Barton