Hi
Just recently purchased A PC104 board with ethernet lan,
Is there any software around or aplications where I can load the software
onto a 16mb disk on chip, I know that Iam using limited memory, but I have
read and seen at exibitions where they have pc104 boards connected to a
desktop with windows 98 running and able to read or communicate with the
pc104 board using a lan connection.
There is dos installed on the pc104 disk on chip, basically what Iam trying
to do is comunicate between dos and windows 98 through tcp/ip.
Using windows 98 lan, just being able to pick up the pc104.
Thanks Craig
Reply by Rick Merrill●April 4, 20042004-04-04
Seven Days wrote:
> Hi
>
> Just recently purchased A PC104 board with ethernet lan,
> Is there any software around or aplications where I can load the software
> onto a 16mb disk on chip, I know that Iam using limited memory, but I have
> read and seen at exibitions where they have pc104 boards connected to a
> desktop with windows 98 running and able to read or communicate with the
> pc104 board using a lan connection.
>
> There is dos installed on the pc104 disk on chip, basically what Iam trying
> to do is comunicate between dos and windows 98 through tcp/ip.
> Using windows 98 lan, just being able to pick up the pc104.
You need DOS drivers for the ethernet chip, and a DOS TCP/IP
"Stack". Then your autoexec.bat file would contain something
resembling this to permit Win98 to r/w files on the PC104:
...
REM The following must be sent to Null!
C:\NET\net initialize > NUL
loadhigh C:\NET\share.EXE
C:\NET\netbind.com
C:\NET\umb.com
C:\NET\NET START NETBEUI
C:\NET\tcptsr.exe
C:\NET\tinyrfc.exe
C:\NET\nmtsr.exe
C:\NET\emsbfr.exe
C:\NET\net start
C:\NET\NET SHARE /DELETE ROOT
...
Reply by Richard●April 4, 20042004-04-04
> Just recently purchased A PC104 board with ethernet lan,
> Is there any software around or aplications where I can load the software
> onto a 16mb disk on chip, I know that Iam using limited memory, but I have
> read and seen at exibitions where they have pc104 boards connected to a
> desktop with windows 98 running and able to read or communicate with the
> pc104 board using a lan connection.
>
> There is dos installed on the pc104 disk on chip, basically what Iam
trying
> to do is comunicate between dos and windows 98 through tcp/ip.
> Using windows 98 lan, just being able to pick up the pc104.
Signal Processing Engineer Seeking a DSP Engineer to tackle complex technical challenges. Requires expertise in DSP algorithms, EW, anti-jam, and datalink vulnerability. Qualifications: Bachelor's degree, Secret Clearance, and proficiency in waveform modulation, LPD waveforms, signal detection, MATLAB, algorithm development, RF, data links, and EW systems. The position is on-site in Huntsville, AL and can support candidates at 3+ or 10+ years of experience.