EmbeddedRelated.com
Forums
The 2024 Embedded Online Conference

Problem in getting Colilo Prompt (mcf5485)

Started by bazooka March 27, 2005
Hi,

I have downloaded the srec file through network using TeraTerm in
windows 2000 SP4.
the first time I downloeded the code, I got the colilo prompt and it
was working
just fine.  now when I reset the board and trying to run the same steps
again
it displays the garbage data.
the following is copy of tera-term output.



ColdFire MCF548X on the M5485EVB
Firmware v3b.1a.1b (Built on Sep  1 2004 16:40:20)
Copyright 1995-2004 Freescale Semiconductor, Inc.

Enter 'help' for help.

dBUG> show
        base: 16
        baud: 115200
      server: 10.0.0.77
      client: 10.0.0.80
     gateway: 10.0.0.1
     netmask: 255.0.0.0
    filename: colilo_mcf5485.srec
    filetype: S-Record
     ethaddr: 00:CF:54:85:CF:01
dBUG> dn
Downloading S-Record 'colilo_mcf5485.srec' from 10.0.0.77
S-record download successful!
TFTP transfer completed
Read 196796 bytes (385 blocks)
dBUG> go 0x1000400
=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=
=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=
=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0=E0



regards

Fakhar

by default colilo operates on 19200 baud rate

set baud 19200

go 0x1000400

FireEngine board boot...
Colilo>