Hello Guys, I'm using OCD commander software of Macraigor Systems for connecting to the LPC device using "WIGGLER" Interface. Does anybody know why always I get this message reported. "Error Response from INITIALIZE: 0x03 initialize_target : cable disconnected (10 : 03)" Ken |
OCD commander
Started by ●February 22, 2005
Reply by ●February 22, 20052005-02-22
kenbnny wrote: > > Hello Guys, > > I'm using OCD commander software of Macraigor Systems for connecting > to the LPC device using "WIGGLER" Interface. > > Does anybody know why always I get this message reported. > "Error Response from INITIALIZE: 0x03 initialize_target : cable > disconnected (10 : 03)" Are you using a Macraigor Wiggler or a home built one ? Recently Macraigor added code to their later ocd commander on ocdremote software to sense a looped back pin to see if a 'real' wiggler or not. Suggestions: * Try an older version of ocd commander (I don't have, but sure someone here will. I only have an older version of ocdremote). * Look back through this list history to see which pins need to be looped back on a home grown wiggler to make it look like a macraigor. * Check your parallel port is in EPP mode (CMOS setup). -- Cheers, Bruce ------------------------------- This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error please notify the system manager. /\\\/\\\/\\\ / / Bruce Paterson / \\\ \\\ \\\ / / Senior Design Engineer / /\\\/\\\/\\\/ / 8 Anzed Court, Mulgrave, Vic, 3170 / / \\\ \\\ \\\ / PO Box 4112, Mulgrave, Vic, 3170, Australia / / \\\/\\\ \\\/ Ph: +61 3 8561 4232 Fax: +61 3 9560 9055 Tele-IP Ltd. Email: Icq: #32015991 WWW: http://www.tele-ip.com VK3TJN ------------------------------- |
Reply by ●February 22, 20052005-02-22
Bruce, I'm using home made wiggler interface as per Schematic given in JTAG.ZIP in group files. Where can I get information regarding which loopback pins connection. Also looking for older version of 2.06version OCD commander software. Thanks, Ken --- In , Bruce Paterson <bruce@t...> wrote: > kenbnny wrote: > > > > > Hello Guys, > > > > I'm using OCD commander software of Macraigor Systems for connecting > > to the LPC device using "WIGGLER" Interface. > > > > Does anybody know why always I get this message reported. > > "Error Response from INITIALIZE: 0x03 initialize_target : cable > > disconnected (10 : 03)" > > Are you using a Macraigor Wiggler or a home built one ? > Recently Macraigor added code to their later ocd commander on ocdremote > software to sense a looped back pin to see if a 'real' wiggler or not. > > Suggestions: > * Try an older version of ocd commander (I don't have, but sure someone > here will. I only have an older version of ocdremote). > * Look back through this list history to see which pins need to be > looped back on a home grown wiggler to make it look like a macraigor. > * Check your parallel port is in EPP mode (CMOS setup). > -- > Cheers, > Bruce > ------------------------------- > This email and any files transmitted with it are confidential and > intended solely for the use of the individual or entity to whom > they are addressed. If you have received this email in error please > notify the system manager. > > /\\\/\\\/\\\ / / Bruce Paterson > / \\\ \\\ \\\ / / Senior Design Engineer > / /\\\/\\\/\\\/ / 8 Anzed Court, Mulgrave, Vic, 3170 > / / \\\ \\\ \\\ / PO Box 4112, Mulgrave, Vic, 3170, Australia > / / \\\/\\\ \\\/ Ph: +61 3 8561 4232 Fax: +61 3 9560 9055 > Tele-IP Ltd. Email: bruce@t... Icq: #32015991 > WWW: http://www.tele-ip.com VK3TJN > ------------------------------- |
Reply by ●February 22, 20052005-02-22
As far as I know, you should connect pin 8 and 15 on the DB25.
________________________________ From: kenbnny [mailto:] Sent: 22 February 2005 08:15 AM To: Subject: [lpc2000] Re: OCD commander Bruce, I'm using home made wiggler interface as per Schematic given in JTAG.ZIP in group files. Where can I get information regarding which loopback pins connection. Also looking for older version of 2.06version OCD commander software. Thanks, Ken --- In , Bruce Paterson <bruce@t...> wrote: > kenbnny wrote: > > > > > Hello Guys, > > > > I'm using OCD commander software of Macraigor Systems for connecting > > to the LPC device using "WIGGLER" Interface. > > > > Does anybody know why always I get this message reported. > > "Error Response from INITIALIZE: 0x03 initialize_target : cable > > disconnected (10 : 03)" > > Are you using a Macraigor Wiggler or a home built one ? > Recently Macraigor added code to their later ocd commander on ocdremote > software to sense a looped back pin to see if a 'real' wiggler or not. > > Suggestions: > * Try an older version of ocd commander (I don't have, but sure someone > here will. I only have an older version of ocdremote). > * Look back through this list history to see which pins need to be > looped back on a home grown wiggler to make it look like a macraigor. > * Check your parallel port is in EPP mode (CMOS setup). > -- > Cheers, > Bruce > ------------------------------- > This email and any files transmitted with it are confidential and > intended solely for the use of the individual or entity to whom > they are addressed. If you have received this email in error please > notify the system manager. > > /\\\/\\\/\\\ / / Bruce Paterson > / \\\ \\\ \\\ / / Senior Design Engineer > / /\\\/\\\/\\\/ / 8 Anzed Court, Mulgrave, Vic, 3170 > / / \\\ \\\ \\\ / PO Box 4112, Mulgrave, Vic, 3170, Australia > / / \\\/\\\ \\\/ Ph: +61 3 8561 4232 Fax: +61 3 9560 9055 > Tele-IP Ltd. Email: bruce@t... Icq: #32015991 > WWW: http://www.tele-ip.com VK3TJN > ------------------------------- ________________________________ > . |
Reply by ●February 22, 20052005-02-22
Hi Ken
Look at http://sysadminforum.com/showthread.php?s64fe3da5c435f497ad868f34952f 99&t#8739&page=2&pp for more info regarding the loopback required on the Wiggler. Cheers, Gawie |
Reply by ●February 22, 20052005-02-22
Guys, A little joy with pin 8 and pin 15 connected on DB25 with latest OCD software at speed 8, I'm able to connect to target, but I'm not able to load file. Any ideas how can I fix this up. Error I get on window. D:\Keil\ARM\Examples\Blinky\Obj\Blinky.elf: downloaded 272 bytes in 0 minutes, 27.28 seconds Error during download PC set to starting address 0x00000000 Regards, Raj --- In , "Gawie de Vos" <gawie.devos@c...> wrote: > Hi Ken > > Look at > http://sysadminforum.com/showthread.php? s64fe3da5c435f497ad868f34952f > 99&t#8739&page=2&pp for more info regarding the loopback required > on the Wiggler. > > Cheers, > > Gawie > > |
Reply by ●February 22, 20052005-02-22
----- Original Message ----- From: "kenbnny" <> To: <> Sent: Tuesday, February 22, 2005 4:02 AM Subject: [lpc2000] OCD commander > > > Hello Guys, > > I'm using OCD commander software of Macraigor Systems for connecting > to the LPC device using "WIGGLER" Interface. > > Does anybody know why always I get this message reported. > "Error Response from INITIALIZE: 0x03 initialize_target : cable > disconnected (10 : 03)" Could be lots of things. Have a look at my web site - I've got a simple LPC210x system there with the Wiggler connections that work for me. You need EPP mode for the printer port. Leon -- Leon Heller, G1HSM http://webspace.webring.com/people/jl/leon_heller/ -- |
Reply by ●February 22, 20052005-02-22
On 22 Feb 2005 at 7:26, kenbnny wrote: > > > Guys, > > A little joy with pin 8 and pin 15 connected on DB25 with latest OCD > software at speed 8, I'm able to connect to target, but I'm not able > to load file. Any ideas how can I fix this up. > > Error I get on window. > > D:\Keil\ARM\Examples\Blinky\Obj\Blinky.elf: downloaded 272 bytes in 0 > minutes, 27.28 seconds > > Error during download > > PC set to starting address 0x00000000 > Do you have RAM at the address you are trying to download ? AFAIK the OCD JTAG download, only downloads to RAM. If you want to program FLASH via JTAG, you need to download a small app that runs in RAM, and uses the normal built-in routines to write to FLASH. Regards Anton Erasmus > > --- In , "Gawie de Vos" <gawie.devos@c...> > wrote: > Hi Ken > > > > Look at > > http://sysadminforum.com/showthread.php? > s64fe3da5c435f497ad868f34952f > 99&t#8739&page=2&pp for more > info regarding the loopback required > on the Wiggler. > > > > > Cheers, > > Gawie > > > > [Non-text portions of this message have been > removed] > > Yahoo! Groups Links > > -- A J Erasmus |