EmbeddedRelated.com
Forums

Crossworks help

Started by quaratie February 11, 2008
Hello,

I am using Crosworks 1.4 Build 1 with MSP-FET430UIF but cannot get the
debugger to work.

I get an "Can't identify target device: No error" message and it does
not connect.

If I try the CrossConnect it will connect but I get a verify error
after download.

The hardware is known good and so is the programming fixture.

I am using msp430f147.

Any ideas would be much appreciated.

Thanks

Beginning Microcontrollers with the MSP430

Hi,

> I am using Crosworks 1.4 Build 1 with MSP-FET430UIF but cannot get the
> debugger to work.

Spawn of the devil, that FET430UIF.

> I get an "Can't identify target device: No error" message and it does
> not connect.

That's what TI return to us. Make sure you've got the correct JTAG
interface style selected in your project.

> If I try the CrossConnect it will connect but I get a verify error
> after download.

I suggest you turn off Block Mode in the CrossConnect target interface.
Some MSPs have problems using block mode over JTAG.

--
Paul Curtis, Rowley Associates Ltd http://www.rowley.co.uk
CrossWorks for ARM, MSP430, AVR, MAXQ, and now Cortex-M3 processors
----- Original Message -----
From: "Paul Curtis"
To:
Sent: Monday, February 11, 2008 9:08 AM
Subject: RE: [msp430] Crossworks help
> Hi,
>
>> I am using Crosworks 1.4 Build 1 with MSP-FET430UIF but cannot get the
>> debugger to work.
>
> Spawn of the devil, that FET430UIF.

I've never had any problems with the Olimex version of that I/F, I've always
been curious about that.

Leon
--
Leon Heller
Amateur radio call-sign G1HSM
Yaesu FT-817ND transceiver
Suzuki SV1000S motorcycle
l...@btinternet.com